Please Choose:

About Athenadental Contact Us service@athenadental.com.au

Forget Password?

Create an accountSign Up

All Category
Dental Lab Equipment
Welding Machine
Mixing Machine
Dental Scanners
Microscope
Refractometer
Vacuum Forming Machine
Dental Articulator
Bunsen Burner
Centrifugal Casting
Compressor & Cutting Lathe
Drill Pin
Vibrator & Visualizer
Polishing Machine
Trimmer
Dental Amalgamator
Dental Loupes
Dental Handpiece
High Speed Handpiece
Slow Speed Handpiece
45 Degree
Increasing Speed Handpiece
Handpiece Accessory
Dental Burs
Push Button Handpiece
Wrench Type Handpiece
Air Motor Handpiece
Straight Nose Handpiece
Fiber Optic Handpiece
Self Powered Handpiece
Contra Angle Handpiece
Handpiece Unit
Reduction Handpiece
Ultrasonic Scaler
LED Ultrasonic Scaler
Water-Bottle Scaler
Non Water-Bottle Scaler
Detachable Scaler Handpiece
Sealed Scaler Handpiece
Ultrasonic Scaler Accessory
Marathon Micro Motor
Micro Motor
Micro Motor Handpiece
Brushless Micro Motor
Intraoral Camera
Wireless Camera
Wired Camera
Dental Curing Light
Curing Light Fiber Tip
Wired Curing Light
Curing Protective Glasses
Wireless Curing Light
Air Syringe
3-Way Air Syringe
3-Way Air Syringe Tip
Air Polisher
Air Prophy
Air Polisher Nozzle
Dental X Rays
Radiation Protection
X Ray Floss Machine
X-Ray Film Reader
Sensor Machine
Disinfection Item
Autoclave Sterilizer
Water Filter
Handpiece Maintenance Item
Denture Flask Cleaner
Ultrasonic Cleaner
Compact Cleaner
Standard Cleaner
Large Capacity Cleaner
Wax Machine
Wax Carving Machine
Wax Heater
Wax Pot
Dental Model
Dental Orthodontics Model
Dental Implant Model
Medical Anatomy Model
Dental Material
Dental File
Orthodontic Pliers
Pen Series
Root Canal Endodontic
Endo Obturation System
Pulp Tester
Apex Locator
Root Canal Treatment Motor
Medical Equipment
Baby Sound Monitor
TDP Lamp
Patient Monitor
Pulse Oximeter
ECG Machine
Dental Tips
Tips for Periodontic
Cavity Preparation Tips
Scaling Tips
Endodontics Tips
Related Products
Home Dental X Rays X Ray Floss Machine Digital Dental Handheld Portable Green X-Ray Machine System 60W 30 KHz High End
Digital Dental Handheld Portable Green X-Ray Machine System 60W 30 KHz High End

Athena Dental

Digital Dental Handheld Portable Green X-Ray Machine System 60W 30 KHz High End

  • Product ID: G181676998
  • AU$629.99
    Qty:
  • Add To Cart In Stock
  • Buy More, Save More:
    2-5 5- Max
    AU$598.00 AU$567.00
  • Promo Details

    AU$10 Off Orders> AU$200
    AU$30 Off Orders > AU$500
    AU$70 Off Orders > AU$1000

    <Prev Page   Next Page>

Item Description

Features:

1. The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees,  located within a distance of 1.2 meters ahead. 
2. Toshiba 0.3mm x 0.3mm micro-focus tube
3. No protective operation room is needed when installing the complete machine
4. Flexible adjustment of position and angle of handpiece
5. Compact in volume, light in weight, convenient for carrying
6.Time is adjustable, high contrast of picture, imaging in focus
7. There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
8. The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
9. Non-film inspection and storage can be realized when corresponding to a sensor
10. SKU: DL-L-BLX5(Z)-110    DL-L-BLX5(Z)-220            

Specifications
Voltage: 110v±10% and 220V±10%  
Power: 24V 8000MA 
Charger: 220V/110V, 50Hz
Tube current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure time: 1-9 seconds optional
Leak radiation: < 20μgy/h(12lb)
Focus Skin Distance: >20cm
Tube voltage: 60KV
Relative Humidity(RH) < 80%
Storage conditions: 5-40 degrees Celsius, relative Humidity
Net weight: 5.5 kg
Dimension: 47 x 42 x 19 cm

Content:
Main Unit x 1
Dental Film Position x 1
Charger x 1
Dental Films for Test x 5
English Manual x 1
Warranty Card x 1
 
 
Operation of the Main Unit
1. Upon receiving, open the box and check the product for possible damage during shipping. 
2. Make sure the fittings on the encasement list are packaged within the box.
3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
4. After the Main Unit and ball head are perfectly fit together, plug in the international standard electrical source, grounding is strongly recommended. 
5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode. 
7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb. 
9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again). Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9. 
11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot lamp is off. Don't keep the main unit long in standby mode.

Points for Attention
1. Make sure the angle of film, tooth, and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
2. Remember to turn the power offwhen work is done.
3. Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
4. After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
5. The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs,  it will not be able to carry out the normal work of filming.
6. When taking pictures, the EXP button could stop the objection and then the machine goes back to the preparation mode.
7. Use high quality tooth film and developing liquid to make clear pictures.
8. Handle the ball head gently while in use, so as not to damage the delicate component. 
9. Do not pull hard on the cable which connects the ball head to the main unit.
10. The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
11. We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
12. If a situation occurs,  preventing the machine from taking regular pictures,  contact the seller to solve the problem instead of trying to service the product yourself. 
13. Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. 
14. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality. 
15. Other requests accordance with the scope of the technical parameters.
16. Please read the manual carefully before using.
 

Athenadental.com.au is one professional dental supplies website which supplies dental equipment in Australia with lowest price guarantee.

  • SUBSCRIBE TO OUR NEWSLETTER Get Exclusive Coupons & New Products Updates