Home Dental X Rays X Ray Floss Machine Dental X-Ray Portable Machine BLX-8

Dental X-Ray Portable Machine BLX-8

Dental X-Ray Portable Machine  BLX-8
  • AU$1328.43 Out of Stock
  • Buy 2-4 For AU$1262.00 Each And Enjoy 5% off

    Buy 5 For AU$1196.00 Each And Enjoy 10% off

  • Please choose a specification

  • - Quantity: +
  • Add To Cart
  • ITEM DESCRIPTION
  • DELIVERY & WARRANTY

Dental X-Ray Portable Machine  BLX-8

Features
1. The tube head is equipped with excellent radiation-shield protection ,except the radial mouth,and tests have shown that the radial index is zero.
2. Toshiba 0.3mm x 0.3mm micro-focus tube.
3. Digital control machine, x-ray output precision, stability
4. No protective operation room is needed when installing the complete machine.
5. Flexible adjustment of position and angle of handpiece,
6. Develop dental film in daylight, no darkroom needed.
7. Compact in volume, light in weight, convenient for carrying.
8.Time is adjustable, high contrast of picture, imaging in focus.

Specifications
110v±10% and 220V±10%  (We stock the item specail for the customer all over the world)
Power: 24V 8000MA Charger: 220V/110V, 50Hz
Tube current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure time: 1-9 seconds optional
Leak radiation: < 20µgy/h(12lb)
Focus Skin Distance: >20cm
Tube voltage: 70KV
Relative Humidity(RH) < 80%
Storage conditions: 5-40 degrees Celsius, relative Humidity
Net weight: 2.5 kg



Packing With
1 x Main Unit
1 x Dental Film position
1 x Charger
5 x Dental Films for test
1 x Warranty Card
1 x English Manual
1 x Deluse Packing Box

 

How to use
1. Operation of the Main Unit
       Upon receiving, open the box and check the product for possible damage during shipping.
       Make sure the fittings on the encasement list are packaged within the box.
       Install the blue ray tube to the foreside of the ball head, then tighten it.
      Turn on the Power, the pilot lamp will be light up.During this time, the digital tube will show the fore setting time. Now the equipment is in standby mode.
      Setting the time (Skip to next step if unneeded) Use the "SET","+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated,  the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
      Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
      Keep the ball head plumb to the tooth projection position; Have the ball head, tooth,  and tooth film steadily mutually plumb.
      After positioning, use the ON/OFF on the main Unit,  to take pictures. (Notice: gently press 0.5 sec to turn it on)
      After exposure to the tube, press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
      Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
      Turn the power off when the work is finished, press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.

2. Developina the Dental film
      Picture the tooth following the right operating procedure of the X-ray Unit,then take the film out from the mouth.
      Use a syringe to extract 4-5 mi of imaging liquid.
      Transfuse the liquid into the bag, nip both the ends and the sides of the bag with thumbs and first fingers(knead the film).
      Open the end of the bag about ten minutes after transfusing the liquid into the bag.
      Take the film out, put it into clear water, and rinse it. Don't wipe the surface of the film with the surface to prevent damage to the image.
      Observe and diagnose after the film becomes dry.
 

3. Points for Attention
      Make sure the angle of film, tooth, and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
      Remember to turn the power 0ffwhen work is done.
      Charge the battery if the machine cannot work and the red lamp lignt
      After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
      The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
      When taking pictures, the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
      Use high quality tooth film and developing liquid to make clear pictures.
      Handle the ball head gently while in use, so as not to damage the delicate component.
      We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
      If a situation occurs,  preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
      Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
      Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
      Other requests accordance with the scope of the technical parameters.


The Angle should be proper while taking a picture. The film should be put vertically behind the tooth to be taken a picture while the case is for the front teeth; and the film should be put transversely behind the tooth to be taken a picture while the case is for the back teeth. The patient should use forefinger to press the film behind the tooth gently.
*Kodak film as the sent samples are strongly recommended.

Reference of the Angles 

Tooth                                  Upper                            Lower

1-2                                         42                                  -15

3                                             45                                  -18

4-5                                         30                                  -10

6-8                                         28                                    -5

 

Reference of the time of exposure

Tooth                                          Adult                                Child                         

Central & Lateral                  2.5-3.25                               2-2.7

Cuspid & 1st Bicuspid         3.2-4                                  2.7-3.5

Upper 5 - 6                             3.5-4                                   3-3.5

Upper 7 - 8                             7.5-8                                   7-7.5

Lower 5 - 6                            4-4.5                                    3.5-4

Lower 7 - 8                            4-4.5                                    3.5-4

 

Trouble Shooting Instructions

Failure                                                                                                   Reason                                                                  Solution

The pilot lamp lights up
but the digital tube unit does net                                         Abnormal Power supply                                           Charge the batterg 
show the fore setting time                                                    Charge the batterg                                  Send the product back to the factory or distributor to repair

                                                                                                          

 No image is taken while the                                             Circuit damaged or connection               Send the product back to the factory or distributor to repair
counting down works                                                           problems 

                                                                                                               

The time setting does not work                                         Error in the control program                      Re-start on the machine

                                                                                                 Problem with the SET button                    Send it for a repair

No counting down after press Start                                  The pilot lamp light is on for the SET      Shut down the SET mode

                                                                                                 The film, tooth, and ball head                    Operate again rightly 
                                                                                                  are not stable while taking a picture

Blurred film                                                                            The film is too far from tooth                       Operate again rightly     
                                                                                                  that is taken a picture

                                                                                                  Wrong angle of taking a picture                 Operate again rightly

The image is too light                                                           The time of exposure is too short               Lengthen the developing time

                                                                                                  The time of exposure is too long                Shorten the developing time

                                                                                                  The film is of poor quality                              Change for a better film

Other possible reasons for a                                              The imaging liquid is of poor quality          Change for a better liquid                                                                                              
Change for a better liquid                                                    

                                                                                                  The temperature is too low                   The temperature is too low while developing the  film in higher temperature        
                                                                                                   while developing the film                     

                                                                                 

Please Note
1.For your safety, do not open the unit. Only professional personnel can inspect and repair the vacuum components and high-voltage parts of the X-ray machine.
2.Tubehead equipped with perfect radiation-shield protection except the radial mouth. The test shows the radial index is zero. Safety is guaranteed.
3.Non-film inspection and storage enabled when corresponding to sensor.

 

 