Home Medical Equipment Patient Monitor Medical Equipment 12.1 inch 6 Parameters Patient Monitoring/Patient Monitor

Medical Equipment 12.1 inch 6 Parameters Patient Monitoring/Patient Monitor

Medical Equipment 12.1 inch 6 Parameters Patient Monitoring/Patient Monitor
  • AU$1211.62
  • Buy 2-4 For AU$1151.00 Each And Enjoy 5% off

    Buy 5 For AU$1090.00 Each And Enjoy 10% off

  • Please choose a specification

  • - Quantity: +
  • Add To Cart
  • ITEM DESCRIPTION
  • DELIVERY & WARRANTY

Medical Equipment 12.1 inch 6 Parameters Patient Monitoring/Patienten Monitor


Features

1. Color TFT Screen, waveform  up to 8 channels
2. Light and portable with build-in rechargeable battery
3. UP to 10 kinds of monitor parameters
4. Arrhythmia analysis, pace-marker detection and S-T Segmentanalysis
5. 72 hour storage and review of trend grams and tables, 40 second review of olographic  wavefo rms.
6. Built-in recorder(option)
7. All-round monitor of adult ,pediatric and neonatal.
8. Electrosurgical unit and defibrillation protected
9. Standard parameters: ECG, NIBP, SPO2,  Respiration,  Temperature, Pulse rate
10. Option parameters: EtCO2, CO, IBP,  Thermal

 

Printer   ECG
5-lead or 3-lead selectable
Input: 5-lead: RA; LA; RL; LL; V or R; L; N; F; C
Lead selection: I; II; III; avR; avL; avF; Vx; CAL
Gain selection: 12.5mm/s, 25mm/s, 50mm/s
Accuracy: ±1bpm or ±1%, whichever is greater
Protection: Withstand 4000VAC/50Hz voltage in  isolation against electrosurgical and defibrillation
Calibration signal: 1mV±5%
Operation modes: Diagnostic, Monitor, Surgery
Alarm range: Adult: 15-300bpm
Pediatric/Neonatal: 15-350bpm
Alarm range: -2.0mV~2.0mV
S-T detection: YES, Arrhythmia analysis: YES
Alarm: YES, audible and visual alarm, alarm events recallable

 

NIBP
Method: Oscillometry
Operation modes: Manual/Automatic/STAT
Measurement unit: mmHg/KPa selectable
Measurement types: Systolic, Diastolic, Mean
Measurement range: Adult: 10-270mmHg
Over-pressure protection: YES
Resolution: 1mmHg
Accuracy: Mean error and standard deviation   per ANSI/AAMI SP-10
Alarm: Systolic,Diastolic,Mean

 

SpO2
Measurement range: 0-100%
Accuracy: ±2digit (70~100%);
0~69% unspecified
Alarm range: 0-100%

 

Respiration
Method: RA-LL impedance
Pediatric/Neonatal: 6-150rpm
Alarm range: Adult: 6-120rpm
Pediatric/Neonatal: 6-150rpm
Apnea alarm: YES

 

Temperature
Resolution: 0.1℃
Channel: Dual-channel
Alarm range: 0-50℃

 

Option
EtCO2
Measurement Mode: Side-stream or mainstream
Measurement range: EtCO2: 0-99mmHg
Accuracy: CO2 concentration
Apnea alarm: YES

 

CO
Method: Thermo-dilution
Measurement range: CO: 0.1-20 lit./min.

 

IBP
Channel: 2 channels
Pressure transducer: Sensitivity: 5( mV/V/mmHg)
Transducer sites: ART, PA, CVP, RAP, LAP, ICP
Alarm range: -10~300mmHg
 